Menu
Index

1.3.1.5.5. Performing tests

To perform tests and report results to the runtime model, you may select the test you wish to report on and then the test result.
 
 
Once you have reported a failure on this test point, you will see that the suspect component list has gone from 10 down to 4 items and the list of possible tests down to 3 from 8.
The model now looks like this:
 
 
The runtime now suggests we test the output of contactor 41. However, we might actually have noticed that PLC output 22 is activated, and so we can report that instead. To report a good result on this test, select it and click Pass.
 
 
 
The results are now:
 
 
and
 
We might also see that contactor 41 is activated so it must be working ok. We can then select the component contactor 41 (not the test) and make it good.
 
 
We are now down to 2 components:
 
 
 
Finally we may again follow the recommendation and test the output of cable 23341.
 
 
If this passes, it means that hoist brake 2 has failed.